Home Categories Send inquiry

GT-AEC2232bX-p Fixed Gas Detector

Technical Parameters

Item

Data

Detected gases

VOC gases

Sampling mode

Pump suction

Operating voltage

DC24±6V

Power consumption

≤3.5W (DC24V)

Electrical interface

NPT3/4"(female)

Protection grade

IP66

Explosion proof grade

ExdⅡCT6Gb

Outer casing

Stainless steel + cast aluminum (shell: cast aluminum)

Dimension

Length × width ×thickness: 242.5mm×177mm×87mm

Weight

About 2.5 kg

Major Features

Patented compound PID joint detection technology

In order to improve the life of the PID sensor, an innovative mode of dual-sensor joint operation is adopted. The semiconductor detection signal is used as the starting signal of the PID detector to reduce the working time of the PID sensor, so the service life of the PID sensor can be greatly improved (2-5 years);

Patented rainproof and dustproof technology

The new multi-purpose rainproof and dustproof cover gives consideration to rain and dust prevention. It can effectively filter 99% impurities and reduce the blocking probability of pumping device;

Secondary polymer membrane filtration device

It can block the interference gas such as water vapor, so that it can work in complex environments such as high humidity and high salt spray;

Temperature compensation function

Built in high sensitivity temperature sensor, automatically compensate the drift caused by the changes of ambient temperature;

Ceramic electrode PID bulb

Using the latest nano-industry ceramic electrode PID bulb, with high stability and accuracy;

LCD liquid crystal display and three-color backlight

It adopts military-grade LCD liquid crystal has good low temperature performance and display effect (clear display under strong light and long distance), with three-color backlight function to make the alarm state more obvious;

With pump blockage alarm

In order to avoid the blockage of the pumping device caused by various environmental or human factors affecting the gas inlet, the blockage alarm function can prompt the user to deal with it in time;

High protection grade

The protection grade reaches IP66.

Model Selection

Model

Signal output

Sensor equipped

Adaptive control system

GQ-AEC2232bX-P

Three-wire (4~20)mA standard signal  and three sets of relay signals

(2 sets of alarm relays and 1 set of fault relay)

Compound PID sensor

ACTION control system:

ACTION gas alarm controllers:

AEC2392a, AEC2392b, AEC2393a , AEC2393b2a-BS, AEC2393b2a-BM

Model Selection

Boundary Dimension

Material cast aluminum; Dimension: Length× width× height: 242.5mm×177mm×87mm Weight: 2.5 kg

Mounting Mode

A. Horizontal pipe-mounted (Holding pipe diameter DN20, DN50 optional)

B. Vertical pipe-mounted (Holding pipe diameter DN20, DN50 optional)

C. Wall-mounted /  Ceiling-mounted


GT-AEC2232bX-p Fixed Gas Detector Related Video: